Investigación clínica
Disponible online el 25 de diciembre de 2025
Experiencia preliminar con el exoscopio VITOM® 3D en el tratamiento microquirúrgico de aneurismas cerebrales
Preliminary experience with VITOM 3D exoscope during microsurgical treatment of cerebral aneurysms
Visitas
11
Joel Caballero-Garcíaa,
Autor para correspondencia
caballero.neuro@gmail.com

Autor para correspondencia.
, Justo Gonzáles Gonzálesb, Guillermo Sánchez Panequec, Luis Horta Claveroc
a Department of Neurosurgery, Medical Cubacenter and Hesburgh Hospital, Santo Domingo, Ecuador
b Department of Neurosurgery, Hermanos Ameijeiras Hospital, La Habana, Cuba
c Department of Neurosurgery, Medical Cubacenter, Santo Domingo, Ecuador
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (5)
Mostrar másMostrar menos
Tablas (3)
Tabla 1. Datos demográficos de los pacientes, evolución clínica, detalles quirúrgicos y resultados
Tablas
Tabla 2. Características de los aneurismas
Tablas
Tabla 3. Series de pacientes con aneurismas intracraneales operados con exoscopios
Tablas
Mostrar másMostrar menos
Resumen
Introducción y objetivos

El empleo de exoscopios 3D en neurocirugía se ha popularizado como una alternativa al microscopio quirúrgico debido a su similar fidelidad, pero superior ergonomía. Sin embargo, las publicaciones de aneurismas cerebrales operados mediante este método de visualización son escasas.

Métodos

Se analizaron las variables clínicas, transoperatorias e imágenes de pacientes con aneurismas cerebrales operados por un mismo cirujano, desde diciembre de 2023 a marzo de 2025, empleando el VITOM® 3D como único método de visualización. La evaluación postoperatoria incluyo la angiotomografía cerebral. Se empleó estadística descriptiva, y se analizaron el tiempo quirúrgico y las complicaciones. Se realizó una discusión extensa de la literatura sobre las experiencias de otros autores empleando exoscopios 4K en el tratamiento microquirúrgico de aneurismas cerebrales, y se compararon los resultados con el estudio.

Resultados

Fueron tratados 88 pacientes con 107 aneurismas cerebrales. Predominó el sexo femenino (65,9%), con un promedio de edad de 52,6 (±13,6) años. Setenta y cuatro pacientes correspondieron a los grados I-III de la clasificación de la WFNS (84,1%) con 14 (15,9%) grado IV. La frecuencia de aneurismas rotos fue del 94,3%, y en el 14,9% de los casos se trataron aneurismas no rotos asociados. La tasa de complicaciones fue del 9,1%. Se encontró un pronóstico favorable en el 83,0% de los pacientes según la escala de Rankin modificada a los 30 días.

Conclusiones

El exoscopio VITOM® 3D es una alternativa válida al microscopio quirúrgico, pues ofrece una visualización comparable, pero superior ergonomía, a un menor costo. Se requiere de la realización de estudios comparativos aleatorizados de grandes series de casos para incrementar el nivel de evidencia.

Palabras clave:
Aneurisma
Exoscopio
Neurocirugía
VITOM® 3D
Abreviaturas:
3D
4K-HD
AComA
TC
VIC
PComA
ACAD
MQ
WFNS
Abstract
Background and objectives

The use of a digital three-dimensional (3D) exoscope system in neurosurgery is increasing as an alternative to the operative microscope due to its similar visual fidelity but superior ergonomics. However, publications on cerebral aneurysms treated with this are scarce.

Methods

Clinical information, surgical records and, imaging of patients with cerebral aneurysms undergoing surgery by a single surgeon, from December 2023 to March 2025, using the VITOM 3D as a vision/magnification method exclusively, is analyzed. Postoperative follow-up included angio-CT scan. Descriptive statistics and data relating to operative time and complications were analyzed. An extensive discussion regarding other authors’ experience using 4K 3D exoscopes in microsurgical clipping of cerebral aneurysms was performed and compared with the present series.

Results

Eighty-eight patients with 107 cerebral aneurysms underwent surgery. Most patients were female (65.9%), with a mean age of 52.6 (±13.6) years. Grades I-III WFNS score was seen in 74 (84.1%) patients, with 14 (15.9%) having grade IV. Ruptured aneurysm rate was 94.3%, but up to 14.9% associated unruptured aneurysms were recorded. Complications rate was 9.1%. A favorable outcome was observed in 83.0% of patients based on modified Rankin Scale score at 30 days.

Conclusion

VITOM 3D exoscope is a valid alternative to the surgical microscope, since it offers comparable visualization but superior ergonomics, at a lower cost. Randomized comparative studies with a larger series of cases should be carried out to increase the level of evidence.

Keywords:
Aneurysm
Exoscope
Neurosurgery
VITOM 3D

Artículo

Opciones para acceder a los textos completos de la publicación Neurocirugía
Socio
Socio de la Sociedad Española de Neurocirugía

Si es la primera vez que accede a la web puede obtener sus claves de acceso poniéndose en contacto con Elsevier España en suscripciones@elsevier.com o a través de su teléfono de Atención al Cliente 902 88 87 40 si llama desde territorio español o del +34 932 418 800 (de 9 a 18h., GMT + 1) si lo hace desde el extranjero.

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".

Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Neurocirugía

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado