Medición bilateral de la saturación yugular de oxígeno
Bilateral jugular venous oxygen saturation measurements
Visitas
1770
M. Pérez Márquez, A.J. Betbesé Roig, G. Rialp Cervera, J.A. Santos Rodríguez, A. Net, L. Marruecos
Servicio de Cuidados Intensivos. Hospital de la Santa Creu i Sant Pau. Universitat Autonoma de Barcelona
Este artículo ha recibido
Información del artículo
Resumen
Bibliografía
Descargar PDF
Estadísticas
Summary
Objective

The objetive of this study was to obtain information about cerebral hemodynamics through retrograde cannulation of both internal jugular veins and monitoring jugular bulb oxigen saturation.

Material and methods

Fourteen (14) patients admitted to our ICU between July of 1994 and April of 1995 were prospectively studied. The intracranial pressure (ICP) was monitored and bilateral cannulation of the internal yugular vein was performed. In 9 patients, one of the two veins was channeled with an optic fiber catheter for continous monitoring at oxigen jugular saturation (SyO2)’ Simultaneus samples were obtained every 8 hours from both jugular veins for measuring SyO2 whenever therapeutic changes were needed or before an increase in the ICP was observed. A total of 140 measurements were performed (mean 10 per patient). A variance analysis, t of student and simple linear regression analysis of the pars obtained in the SyO2 were performed. Furthermore we studied the influence of the type of intracranial pathology as assessed by cranial computerized tomography (CT), as well as at different levels of raised IPC.

Results

Average monitoring time was 7.2 days (311). The brain injury in the CT was considered focal in 8 patients and mixed (focal + diffused) in 6. The correlation between the left and right SyO2 was r=0.68 (p<0.005). In patients with focal CT lesions correlation was r=0.58 (p<0.005), with true regression Y= 32 + 04X. Mean values were 61.8±9% for the right jugular and 67.6±12% for the left (p<0.005). The correlation in patients with mixed CT lesions was r=0.79 (p<0.005) with true regression Y= 18 + O.72X. The average value was 70.9±11% for the rigth jugular and 71±12% for the left jugular vein (difference not significant). The correlation coefficient for ICP levels of <20, >20, >30 and >40mm Hg was r=0.66, r=0.79, r=0.85 and r=0.89, respectively. Clinical discordance between bilateral measurements was over 30% of these in 50% of the patients.

Conclusion

The SyO2 obtained through retrograde cannulation from both jugular veins maintains a correct positive correlation that improves in intracranial hypertension situations. Correlation is better in patients with mixed CT lesion than in those with focal pathology. Our study could not determine which of the two jugular veins provided more reliable information of about intracranial hemodynamics. Consequently, we do not support the used of bilateral SyO2 monitoring in the clinical rutine.

Key words:
Acute head injury
Cerebral bood flow
Jugular vein

Artículo

Opciones para acceder a los textos completos de la publicación Neurocirugía
Socio
Socio de la Sociedad Española de Neurocirugía

Si es la primera vez que accede a la web puede obtener sus claves de acceso poniéndose en contacto con Elsevier España en suscripciones@elsevier.com o a través de su teléfono de Atención al Cliente 902 88 87 40 si llama desde territorio español o del +34 932 418 800 (de 9 a 18h., GMT + 1) si lo hace desde el extranjero.

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".

Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Neurocirugía

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
Email
Idiomas
Neurocirugía
Opciones de artículo
Herramientas
es en

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?